{"title":"AquaWiz","description":"\u003ch1 class=\"collection-hero__title\"\u003eAquaWiz\u003c\/h1\u003e\n\u003cdiv class=\"collection-hero__description rte\"\u003e\n\u003cp\u003e\u003cspan\u003eWe are a coral equipment manufacturer dedicated to simplifying coral cultivation through automation and intelligent control. Our mission is to make reef-keeping easier and more accessible for all enthusiasts. Currently, we offer two patented flagship products:\u003c\/span\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\u003cspan\u003eKH Guardian – A reagent-free, maintenance-free KH controller that continuously monitors and maintains alkalinity levels without the need for consumables.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAI Calcium Reactor Controller – The world’s first AI-powered controller that fully automates the operation of a calcium reactor, from CO₂ regulation to flow control and dKH stabilization.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cspan\u003eW\u003c\/span\u003e\u003cspan\u003eith AquaWiz, users can enjoy a smarter, more effortless reefing experience.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","products":[{"product_id":"aquawiz-kh-controller-gen-4","title":"AquaWiz KH Controller Gen 4","description":"\u003cdiv\u003eMaintaining KH level (alkalinity)  in a tank can be challenging. The conventional method of alkalinity measurement is to mix an acid such as HCL with a sample solution of tank water. And record the change of PH values before and after the mixing. The alkalinity of the water sample is then obtained as a function of PH value changed, and the amount of acid added. It’s a complex and time consuming process that you may have to perform over and over.\u003c\/div\u003e\n\u003cdiv\u003eSay good-bye to cans and bottles of test solutions and the tedious daily routine! This revolutionary invention, AquaWiz KH controller™, automatically measures and optionally maintains the KH level in your tank. No test solution needed. All you need to prepare is a “reference solution” that can best sustain life in your tank. It can be your existing tank of seawater with stable alkalinity. The reference solution is recycled and reused during the whole measurement process. No wastewater is dumped, and no acid solution is produced. It’s an environmentally friendly solution that can do both KH measurement and KH control.\u003c\/div\u003e\n\u003cdiv\u003eNo test solution needed ! No pollutant produced ! No more test solution shortage.\u003c\/div\u003e\n\u003cdiv\u003eCoral consumes different amounts of KH per hour. It is necessary to measure KH every hour.\u003c\/div\u003e\n\u003cdiv\u003eResumes automatically after power outage.\u003c\/div\u003e\n\u003cdiv\u003eNew water level control for reference water reservoir.\u003c\/div\u003e\n\u003cdiv\u003eControls KH through a built-in dosing pump to dosing KH solution.\u003c\/div\u003e\n\u003cdiv\u003eKH to PH converting BNC plug to enable reading and control KH by a PH controller.\u003c\/div\u003e\n\u003cdiv\u003eSpecific PH electrode, no extra calibration step is needed.\u003c\/div\u003e\n\u003cdiv\u003eDetects the aging of the PH electrode, automatically reminds for replacement.\u003c\/div\u003e\n\u003cdiv\u003eNo more worry when you are out of town ! Notify through email when out of specification. Check KH status remotely in a line chart through\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"http:\/\/www.aquawiz.net\/\" data-saferedirecturl=\"https:\/\/www.google.com\/url?q=http:\/\/www.aquawiz.net\u0026amp;source=gmail\u0026amp;ust=1706119728232000\u0026amp;usg=AOvVaw0dDde6YQMvrgdSUgrfxI_d\" rel=\"noopener noreferrer\" target=\"_blank\"\u003ewww.aquawiz.net\u003c\/a\u003e.\u003c\/div\u003e\n\u003cdiv\u003eMeasurement intervals can be set to 1~6 hours through the web interface.\u003c\/div\u003e\n\u003cdiv\u003eEnclosed motor and pump, and sleep timer setting.\u003c\/div\u003e\n\u003cdiv\u003eOpen lid design for easy installation and maintenance.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eBefore you use Aquawiz make sure there is no stray voltage in your system from other devices as this will affect the performance of the device.\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003eSpecification:\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003ePower adapter: Input AC100V ~~240V, 50\/60HZ. Output: DC 12V 5A, 5.5 mm plug.\u003c\/div\u003e\n\u003cdiv\u003ePH probe: BNC connector, PH probe for aquarium use.\u003c\/div\u003e\n\u003cdiv\u003eControl Output: DC 3.5mm \/ 1.35 mm jack, 12V 1A. Output active when the KH measurement value is below the target KH value.\u003c\/div\u003e\n\u003cdiv\u003eKH precision: ± 0.05 KH.\u003c\/div\u003e\n\u003cdiv\u003eKH to PH output accuracy +- 0.01.\u003c\/div\u003e\n\u003cdiv\u003ePeristaltic tube inner \/ outer diameter: 3mm \/ 5mm.\u003c\/div\u003e\n\u003cdiv\u003eCapacity of reference seawater reservoir: 20 oz (0.6L).\u003c\/div\u003e\n\u003cdiv\u003eSize: 7.08” X 7.08”X 7.48” (18X18X19 CM)\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cb\u003eLarge Difference Between Device Readings and Manual Test Results — Possible Causes and Troubleshooting, check page below:\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/collectorscorals.com\/pages\/aquawiz-trouble-shooting\"\u003eAquawiz Trouble Shooting – Collectors Corals\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Collectors Corals","offers":[{"title":"Default Title","offer_id":46530129264815,"sku":"sku-43474982109374","price":879.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/7701\/3423\/files\/1_05f881dc-48e4-4bba-ac05-2c7b08b945ad.jpg?v=1769928866"},{"product_id":"aquawiz-cra-calcium-reactor-controller","title":"AquaWiz CRA Calcium Reactor Controller","description":"\u003cp\u003e\u003cspan class=\"c12 c37\"\u003eAquaWiz CRA Calcium Reactor Controller\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c17\"\u003e \u003c\/p\u003e\n\u003cp class=\"c22 c26\"\u003e\u003cspan class=\"c13 c6 c12\"\u003eAquaWiz CRA™, Calcium Reactor Controller AquaWiz, \u003c\/span\u003e\u003cspan class=\"c2\"\u003eis an innovative equipment to control water flow and CO2 inlet of calcium reactor，It makes calcium reactor  easily to be operated, and controlled remotely through the internet. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c22 c26\"\u003e\u003cspan class=\"c30 c12\"\u003eWhy using Calcium Reactor\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c22\"\u003e\u003cspan class=\"c13 c6\"\u003eCorals in your tank consume KH\/Ca\/Mg to build their skeletons. In general, a calcium reactor melts media by CO2 input to produce and maintain the perfect ratio of KH\/Ca\/Mg, which is less dependent on the ratio of Ca\/Mg media. \u003c\/span\u003e\u003cspan class=\"c13\"\u003eThe media usually lasts a long time before the need to add them. If using a conventional Dosing Pump system, you need a lot of time to prepare, measure, and adjust KH\/Ca\/Mg concentrations for each solution. The unbalance of ions becomes an issue for a long run. If using a Calcium Reactor with proper media, KH\/Ca\/Mg ratio can be maintained perfectly without ion-unbalanced issues.   \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c22 c26\"\u003e\u003cspan class=\"c12 c30\"\u003eDifficulties of using Calcium Reactor:\u003c\/span\u003e\u003cspan class=\"c13 c12 c20\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003col class=\"c31 lst-kix_902optz7pdix-0 start\" start=\"1\"\u003e\n\u003cli class=\"c1 li-bullet-0\"\u003e\u003cspan class=\"c3\"\u003eIt is difficult to maintain constant CO2 bubbling and water flow rate, which drift day to day, and need to watch and adjust them daily to weekly.  if the water outlet is in the dropping mode, the water path is easily blocked.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"c1 li-bullet-0\"\u003e\u003cspan class=\"c3\"\u003eIt is difficult to follow the change of KH\/Ca\/Mg demand due to the growth of coral, or due to poor environments, like nutrition depletion or lightning failure, and result in low KH or high KH. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"c1 li-bullet-0\"\u003e\u003cspan class=\"c13\"\u003eFrom observation, KH\/Ca\/Mg demand of coral changes hour to hour. It consumes less KH\/Ca\/Mg after lightning-off, and more when lightning-on, and reaches peak after several hours of light-on. Conventional constant supply mode of the calcium reactor’s operation fails to follow this trend and results in very unstable KH, especially for high demand tanks. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"c1 li-bullet-0\"\u003e\u003cspan class=\"c3\"\u003eNot friendly for a new hand to understand the know-how and adjustment.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"c18\"\u003e \u003c\/p\u003e\n\u003cp class=\"c22 c26\"\u003e\u003cspan class=\"c4\"\u003eAquaWiz CRA Calcium Reactor Controller make it easier:\u003c\/span\u003e\u003c\/p\u003e\n\u003col class=\"c31 lst-kix_adsoapjuklzm-0 start\" start=\"1\"\u003e\n\u003cli class=\"c1 li-bullet-0\"\u003e\u003cspan class=\"c3\"\u003eAquaWiz CRA is capable of setting CO2 bubbling amounts for every hour. With input of KH readings measured from an AquaWiz KH controller (KHA), the supply of KH from a calcium reactor can be maintained and adjusted automatically to a preset KH target.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"c1 li-bullet-0\"\u003e\u003cspan class=\"c3\"\u003e Automatic water outlet control to maintain stable KH.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"c1 li-bullet-0\"\u003e\u003cspan class=\"c3\"\u003eFrom results of install bases, KH ranges can be stabilized within 0.2 ~ 0.6 dKH. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"c1 li-bullet-0\"\u003e\u003cspan class=\"c13\"\u003eWebsite to monitor\/adjust operation of CRA when going outside. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"c1 li-bullet-0\"\u003e\u003cspan class=\"c3\"\u003eThe checklist below is required for operation (1) block of water path (2) backstream of water into CRA CO2 out port (3) CO2 canister pressure (4) amount of Ca\/Mg media.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"c17\"\u003e \u003c\/p\u003e\n\u003cp class=\"c22 c26\"\u003e\u003cspan class=\"c4\"\u003eAdvanced operation of AquaWiz CRA:\u003c\/span\u003e\u003c\/p\u003e\n\u003col class=\"c31 lst-kix_4l2ivmuy4hfj-0 start\" start=\"1\"\u003e\n\u003cli class=\"c1 li-bullet-0\"\u003e\u003cspan class=\"c3\"\u003eFrom the weekly chart, if CO2 output decreases from day to day, then something is wrong and results in decreased consumption of KH. It might be lightning intensity, nutrition problem, or an infection. Actions can be taken as soon as possible to prevent serious issues.  \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"c1 li-bullet-0\"\u003e\u003cspan class=\"c3\"\u003eWhat is the best duration for water change? Please check the trend of CO2 output. If trend up obviously after water change, then shortening the duration of water change is recommended. This method could be applied to nutrition\/elements supply, lightning intensity\/duration, or new equipment.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"c17\"\u003e \u003c\/p\u003e\n\u003cp class=\"c9\"\u003e\u003cspan\u003e\u003cimg alt=\"\" src=\"https:\/\/lh7-us.googleusercontent.com\/WgVDKSC4dBXUiJBW2nWojSveSQM3O5PMr4HDlqKCmS98puD8q3KwSfzOf1fqReE--t74VblRNsaHleoYYXF7W4s_dxp4mcel6ouF9xGs9d2bIg057gn598Zlq625qC64maxs00DDJR28U4En\" title=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c16 c26\"\u003e\u003cspan\u003e\u003cimg alt=\"\" src=\"https:\/\/lh7-us.googleusercontent.com\/F3GLBptqafOoo-yAlx5vQ_5Bi01jdBd-eZn_K7OMnbFgRNWOVj81hwamn2gztXO4kvqnhcdralwOuAe1B3cdNs8yDQCd6jbA438tqZmpwwKN9-5fOOoeB5Dgjk_DWKCNTT3xHkNkMenOOJ3E\" title=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c16 c26\"\u003e\u003cspan class=\"c5\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c15 c26\"\u003e \u003c\/p\u003e\n\u003cp class=\"c16 c26\"\u003e\u003cspan\u003e\u003cimg alt=\"\" src=\"https:\/\/lh7-us.googleusercontent.com\/WV6LVOuhgzrm95JVdjHyLIFa6tQUg5gdtUhadZ7Y5RNq0-WlaKun82iGjMC8MXbBXUS_SjYoO7VKsmRl5jLiFpanRr2F9ZKS9QDc-2K-HAPm_FAIlwJNdm455YY58-1ODgTHRD3u5xhQCLUU\" title=\"\"\u003e\u003c\/span\u003e\u003cspan class=\"c5\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c15 c26\"\u003e \u003c\/p\u003e\n\u003cp class=\"c16 c26\"\u003e\u003cspan\u003e\u003cimg alt=\"\" src=\"https:\/\/lh7-us.googleusercontent.com\/Lpj5GLiv2ywioQ4jRfM2Uf8fasYFhohWSleNLatsgxc5M0JT_djdWGKLk5I4kEgdZw0qwn-CaIT9fWh5BJdRiYbpsjQRDwufEpWo6I8Iy-iFEt1ZLf8oLHV5miz2f-rUso8gl6FIgw9YWOHy\" title=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c8 c23 c26\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"c10 c26\" id=\"h.4ejlfabregg3\"\u003e\u003cspan class=\"c4\"\u003eFunctions:\u003c\/span\u003e\u003c\/h2\u003e\n\u003col class=\"c31 lst-kix_t6y55qg33ccc-0 start\" start=\"1\"\u003e\n\u003cli class=\"c1 li-bullet-0\"\u003e\u003cspan class=\"c3\"\u003eWater flow control: Non-metal valve to control opening. Daily fully opening to flush flow path. Two flow modes for small and large KH demand. Valve keeps opening pre-setting after power off.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"c1 li-bullet-0\"\u003e\u003cspan class=\"c3\"\u003eCO2 output control: set 24 hours’ CO2 bubbling count with ~30cc per bubble. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"c1 li-bullet-0\"\u003e\u003cspan class=\"c3\"\u003eAuto tuning: adjust the CO2 output automatically with the KH demand. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"c1 li-bullet-0\"\u003e\u003cspan class=\"c3\"\u003eAquaWiz KH Controller (KHA) transmits KH reading to CRA wirelessly for auto tuning function. If no KHA available, no auto tuning function.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"c1 li-bullet-0\"\u003e\u003cspan class=\"c13\"\u003ePH monitoring (optional): More CO2 bubbling count, then more KH\/Ca\/Mg produced. PH reading in CaRx is not required. If a PH probe is installed, then PH reading can be monitored on the website.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 class=\"c10 c26\" id=\"h.jp3t1ux37o17\"\u003e\n\u003cspan class=\"c12\"\u003eInstalltion\u003c\/span\u003e\u003cspan class=\"c4\"\u003e:\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ch2 class=\"c24\" id=\"h.dgssq2r2bxs1\"\u003e\u003cspan\u003e\u003cimg alt=\"\" src=\"https:\/\/lh7-us.googleusercontent.com\/5YIzdBija2ii40B-qoLiHzjllUDi2zflxf0gzAb6n9QB5Qr5s0hVRj7E9lRf1xgYfv424qjiH4mvqLmcEPqoI5W4IK-FpiLTfgRYg82dnsC9fog9uR9xVqEF2c1bht7t4muwvlLMMo5wxlk5\" title=\"\"\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2 class=\"c24\" id=\"h.tvw6oom4dz43\"\u003e\u003cspan\u003e\u003cimg alt=\"\" src=\"https:\/\/lh7-us.googleusercontent.com\/_v2o820K8PYvnv1M1p3fI8ATAOcv9sHItInMnwB_mDpRjdhX_PoUSMGKVCDWvaJEubifo5xkU2sKeLPMycY9cZULgVHlSccliFafo9e3tQu8QVPjUQQpov9GKdt6diD4fOYZnE57kJ8sOYS-\" title=\"\"\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2 class=\"c10 c26\" id=\"h.oo9czerg8jw6\"\u003e\n\u003cspan class=\"c12\"\u003eLCD Display:\u003c\/span\u003e\u003cspan\u003e    \u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp class=\"c9\"\u003e\u003cspan\u003e\u003cimg alt=\"\" id=\"ed.searcqp5ci25\" src=\"https:\/\/docs.google.com\/drawings\/d\/spwDsjETgd0BI4Qq9FUdBkw\/image?parent=e\/2PACX-1vQOmBQ3aQ0qloAZFooWwYHel8__5saG0wrWpEHq2GfHCc9D0c_Ti2Nrmnzr-ycsQ_79PIyJxxCIldaS\u0026amp;rev=1\u0026amp;drawingRevisionAccessToken=cU2Tpr16JeXP5g\u0026amp;h=75\u0026amp;w=253\u0026amp;ac=1\" title=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c21\"\u003e\u003cspan class=\"c13 c12\"\u003e0.51:\u003c\/span\u003e\u003cspan class=\"c3\"\u003e KH difference between reading and target value, which was sent from KHA wirelessly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c21\"\u003e\u003cspan class=\"c12 c13\"\u003e5.51:\u003c\/span\u003e\u003cspan class=\"c3\"\u003e PH value inside calcium reactor if there is a PH probe installed and BNC cable plug-in CRA.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c21\"\u003e\u003cspan class=\"c13 c12\"\u003eM1A2:\u003c\/span\u003e\u003cspan class=\"c3\"\u003e  Control mode 1 and step A2 \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c21\"\u003e\u003cspan class=\"c13 c12\"\u003e015\/017\/010:\u003c\/span\u003e\u003cspan class=\"c3\"\u003e 015: current CO2 bubble count. 017: calculated CO2 bubble count needed in this hour. 010: presetted CO2 bubble count of this hour.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c21\"\u003e\u003cspan class=\"c13 c12\"\u003e20:15:\u003c\/span\u003e\u003cspan class=\"c3\"\u003e current time, the clock is automatically synchronized with internet time.  \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c17\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"c10 c26\" id=\"h.hnim88f5yccn\"\u003e\u003cspan class=\"c6 c12\"\u003eWebsite Chart:\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"c9\"\u003e\u003cspan\u003e\u003cimg alt=\"\" src=\"https:\/\/lh7-us.googleusercontent.com\/KnFg0uyoxHAMx3G2A8inJsAafsDM87b8UPvGCUK1XRrgZ-q1uub645Y0uuKLbgvHBiSgiyd5HtaYMVYX9uuLJZlSn1T-IhhifJbgBLgzbxNrmIfe0DWKTNmP7mT5UJTyNsRNoUJToqBgeAbq\" title=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c22\"\u003e\u003cspan class=\"c13 c6 c29\"\u003eblue line d-KH \u003c\/span\u003e\u003cspan class=\"c2\"\u003e-- KH reading - KH target\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c22\"\u003e\u003cspan class=\"c13 c6 c41\"\u003egreen line CaRx PH\u003c\/span\u003e\u003cspan class=\"c2\"\u003e -- PH minimum within this hour\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c22\"\u003e\u003cspan class=\"c13 c6 c40\"\u003eyellow line CO2 \u003c\/span\u003e\u003cspan class=\"c2\"\u003e-- CO2 output this hour\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c17\"\u003e \u003c\/p\u003e\n\u003cp class=\"c9 c23\"\u003e \u003c\/p\u003e\n\u003cp class=\"c17\"\u003e \u003c\/p\u003e\n\u003cp class=\"c22 c26\"\u003e\u003cspan class=\"c30 c6 c12\"\u003eWebsite Settings:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c9\"\u003e\u003cspan\u003e\u003cimg alt=\"\" src=\"https:\/\/lh7-us.googleusercontent.com\/S1y6oCBbyIcmeIV3tqKV5TsBwb_vLPoEFvNzANST7wRJKB7Wp2ZRxf1EGlSl4s_bR3IfUd2yyYSpTr9r81XhhoS3-0JmLnY-_JqePsz2HXaIwueWCbLyuQhGrK0zC3CTJuyjECVMXrWyAKLp\" title=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"c10\" id=\"h.t5a9n96tl4xg\"\u003e\n\u003cspan class=\"c12\"\u003eSpecification\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\n\u003c\/h2\u003e\n\u003col class=\"c31 lst-kix_4nx8asx1nbox-0 start\" start=\"1\"\u003e\n\u003cli class=\"c32 li-bullet-0\"\u003e\u003cspan class=\"c2\"\u003ePower: input AC100V~240V，50~60HZ。output: DC 12V  1A，5.5 mm plug。\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"c32 li-bullet-0\"\u003e\u003cspan class=\"c2\"\u003ePH probe: habby grad or industry grad PH probe with BNC connector.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"c32 li-bullet-0\"\u003e\u003cspan class=\"c2\"\u003eTube for CO2 in.out : 6mm PU high pressure tube.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"c32 li-bullet-0\"\u003e\u003cspan class=\"c2\"\u003eDimension: 17 X 13 X 7  cm.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"c22 c23\"\u003e \u003c\/p\u003e\n\u003cp class=\"c22 c23\"\u003e \u003c\/p\u003e\n\u003cp class=\"c22 c23\"\u003e \u003c\/p\u003e\n\u003cp class=\"c22 c23\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"c10\" id=\"h.iw2o5pgxwz83\"\u003e\u003cspan class=\"c4\"\u003eCustomer demo:\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"c14\"\u003e\u003cspan class=\"c3\"\u003e5 ft tank with high coral density. CaRx is JNS T-3 10L\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c14\"\u003e\u003cspan class=\"c3\"\u003eAquaWiz KHA (measure) + CRA (Control CaRx) Steadily output KH\/Ca\/Mg\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c14\"\u003e\u003cspan class=\"c3\"\u003eNo additional Ca\/Mg supply by dosing pumps is required\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c14\"\u003e\u003cspan class=\"c3\"\u003eVideo:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c14\"\u003e\u003cspan class=\"c3\"\u003ehttps:\/\/v.douyin.com\/Ysba3PL\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c8 c23\"\u003e \u003c\/p\u003e\n\u003cp class=\"c16\"\u003e\u003cspan\u003e\u003cimg alt=\"\" src=\"https:\/\/lh7-us.googleusercontent.com\/LsjdLYN6Q6bPAK6zqgFeDkHDrWRD7yzm9mqEX1R2aEC05LrGxeRvc4dDs1JzC-XgxCt3hz-OD76bq5x-qQ_jZky1tzKmegRI5v72_9e54XbiWeaBfUUFNfoM2dsa4Zm10YVicG06BwGHXrc\" title=\"\"\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cimg alt=\"\" src=\"https:\/\/lh7-us.googleusercontent.com\/EDFL3VyYMK8dPLWhbr5--Qg2fakX1DGq7kEufFTMWk3NYOkRHbN8731wJGRMD1FmojuHCoV3v4S0LuAGcpMhN0G7NTHXa3BWGR1bqP835Sbsx4y0bzGDo3crUjd-zyP4qSMRVUhsHNUaK7M\" title=\"\"\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cimg alt=\"\" src=\"https:\/\/lh7-us.googleusercontent.com\/SJH_MngGCrJirRwIXWn5GqFLpLiwkBFWJB3swZ-ITjJwwqOygCBnVWtD8T50AC8XYuVYgGLjCrvhUa0UratGdnodWNGBm4g4zLWDdQvHYz05sFoIN-XOmVU4OQOSmygsrKyiITdMCO03yzo\" title=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c15\"\u003e \u003c\/p\u003e\n\u003cp class=\"c7\"\u003e\u003cspan class=\"c13\"\u003e5 ft tank, 800L, SPS density medium. KHA measures KH hourly, CRA controls flow and CO2 gas to JNS T-2 5L calcium reactor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c15\"\u003e \u003c\/p\u003e\n\u003cp class=\"c16\"\u003e\u003cspan\u003e\u003cimg alt=\"\" src=\"https:\/\/lh7-us.googleusercontent.com\/KgNpqKDAe2Pjjigp6n0tuXuTqxunUoYbtJrK7Jk4bg6j8Yk-hs7BJMRfM1BkWTDXETLZK12txx9Zp_kILjD3AxqN0X14JDQMJAda7flnLV0oc8BcMeB4ANvsfnFLbDLirbxcjHsZUuRMjiw\" title=\"\"\u003e\u003c\/span\u003e\u003cspan class=\"c25\"\u003e A\u003c\/span\u003e\u003cspan\u003e\u003cimg alt=\"\" src=\"https:\/\/lh7-us.googleusercontent.com\/mXxhpwRT9U8ccJlONYRlFADlqsE_yJFfCk8BwmemhspA_orWz0UpJaLf6bJs8Q_wq7T28Qn5KeLbbUEHML-NXCkD_59siHD_mGMFB3lcXAOh3xEFqtiSxLKubeRpi1ZpWDYe0fYudktkVrc\" title=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c15\"\u003e \u003c\/p\u003e\n\u003cp class=\"c15\"\u003e \u003c\/p\u003e\n\u003cp class=\"c15\"\u003e \u003c\/p\u003e\n\u003cp class=\"c15\"\u003e \u003c\/p\u003e\n\u003cp class=\"c8\"\u003e\u003cspan class=\"c3\"\u003e8 ft tank, SPS density medium. KHA measures KH hourly, CRA control flow and CO2 gas to JNS T-3 10L calcium reactor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c8\"\u003e\u003cspan\u003e\u003cimg alt=\"\" src=\"https:\/\/lh7-us.googleusercontent.com\/Im1tsp3aOtAmnajit0wZRRz82pde5Qu1nigdAYOnQsGzWKET36x7yZLHahNSN5Ixr7EfvNUiNXxNw6XV6xJxtb5dwM0EwdBPx-g9myZ6CWMDAdPjE80idleMgH1qVW4HORYiBdLs8swoGqI\" title=\"\"\u003e\u003c\/span\u003e\u003cspan class=\"c13 c33\"\u003e \u003c\/span\u003e\u003cspan\u003e\u003cimg alt=\"\" src=\"https:\/\/lh7-us.googleusercontent.com\/L-fixLi_tdbx6JPDYwdcNIzZztQ1OidMthpxZYKBO377ts-uU6aTiTs9TkALcxxLWOTk9_KjZBubCweYxbBGzWihTW0QnJXwb5_nBWchueRjRs_mp5VTOZyhkHuow1_6iMqzfsgFz-306pI\" title=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c8 c23\"\u003e \u003c\/p\u003e\n\u003cp class=\"c8\"\u003e\u003cspan class=\"c13\"\u003e5 ft tank with medium coral density. CaRx is HC AQUA CA100PRO with 5 L \u003c\/span\u003e\u003cspan class=\"c13\"\u003evolume\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c14\"\u003e\u003cspan class=\"c3\"\u003eAquaWiz KHA (measure) + CRA (Control CaRx). Steadily output KH\/Ca\/Mg\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c8\"\u003e\u003cspan\u003e\u003cimg alt=\"\" src=\"https:\/\/lh7-us.googleusercontent.com\/jBulrjQT51ihCJzcv-lNH26cPq6eMJkzHP557j-53-med2PTNj5NUB1xtTWYvR4bYvHZS4F8RxD8N-y1qEemc1NAPp_8P6nCGcGwolL0bs1s2tyofApu21-gc64DeHCNuW0Ea23BR9LtZ_4\" title=\"\"\u003e\u003c\/span\u003e\u003cspan class=\"c25\"\u003e \u003c\/span\u003e\u003cspan\u003e\u003cimg alt=\"\" src=\"https:\/\/lh7-us.googleusercontent.com\/9Mw7X0TWKhD_n57IQCIfqtyPU53Zc8JJp60pe5PC2z2e7YAAOFINQLVkWBotkN_6OTPPAOPsRbyd_0P2K8TpM5OJAc_8z7Lm-4hNDILXbV5SLtciGleW_8Sn2NYvmAf7UItyYhsvMvpsMjo\" title=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c35\"\u003e\u003cspan class=\"c27 c25\"\u003eKHA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c7\"\u003e\u003cspan class=\"c3\"\u003e5 ft tank, 800L, SPS density high, consume 3.0 dKH per day. Equipped Korallin C4001 10L calcium reactor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"c16\"\u003e\u003cspan\u003e\u003cimg alt=\"\" src=\"https:\/\/lh7-us.googleusercontent.com\/hrEG-1nGkYLVzsO8kICK6jMB7o5abAnFIOzTuASCn6SEfDarq1JcRPJe7VCnF_JxUbVeNJ5ubVqy6oXwJnxtat7H56HF6njiTuXRYdMu3Tqdwz206YOLgamBQpYj5TCEDAt6mQtC4HRFKes\" title=\"\"\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e\u003cimg alt=\"\" src=\"https:\/\/lh7-us.googleusercontent.com\/zgoemKuxgnQmeTzjNmYCw7fhVgdXFHp5bsiUyMURD4unirV4T5PRL-STPIgEGKYRLrBs-xUQHvYXkf7opbRnm9xzX-VnLR2Js-4PxxwyzVIyBhDkbPLzlAg7OGN1vvSOVwktM5JC8-de4ec\" title=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Collectors Corals","offers":[{"title":"Default Title","offer_id":46530212954287,"sku":"sku-43990211559614","price":512.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/7701\/3423\/files\/image.png?v=1769929772"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/7701\/3423\/collections\/Aquawiz_blau_von_vorne_RGB_1200x1200px_35405.png?v=1769964805","url":"https:\/\/gemstatecorals.com\/collections\/aquawiz.oembed","provider":"Gem State Corals","version":"1.0","type":"link"}